Lightning and the Trailer Sailor,
To ground or not?
by arlyn stewart
As a trailer sailor who enjoys cruising, and who has experienced some encounters with lightning, I find the perspectives among
sailors about lightning to be quite interesting and varied. In an
area where predictability is hard to come by and emotions flow easily... the
opportunity for variety has fertile ground. It's my hope to
add perspective by further examination, rather than fueling more
emotions.
Unfortunately, in order to advance a perspective, its sometimes
necessary to make space. Because so much acceptance has been
given to a Florida Sea Grant study produced by Dr. Ewen Thomson, I feel that the only place to begin is
with it. First, when someone advances a theory,
the conclusions used to argue that theory are open for critical
review. This is not only natural but prudent. Until
questioned, many theories find common acceptance but to quote a friend who very recently said, " Good science is founded in quantifying....(measuring)". Has Dr. Thomson's theory about the nature of sailboats and lightning been substantiated?
Unfortunately,
lightning is such an unpredictable and powerful phenomena that it is
very difficult to provide laboratory testing. Findings
about the nature of lightning
therefore, may often come from statistics or empirical research. In fact, these
are the support of Dr. Thomson's theory. When evaluating however, there seems cause to question his applications.
Of concern is the weight that Dr.
Thomson's study brings to bear upon the small boat
sailor or as we often call ourselves, trailer sailors. There
seems often a need by small boat enthusiast to emulate their larger
blue
water friends. Sometimes however, their paths diverge. I
hope this offering covers some of hose differences and possibly frees up some of
the anxieties that are
produced by the growing pressure to provide grounding systems on boats
perhaps not very conducive to them.
The following section is from Dr. Thomson's presentation and serves as the
heart of his theory and conclusions.
__________________________________________________________
Attachment
As the negatively-charged stepped leader moves downwards,
it induces a positive charge on the ground below. When the tip of the leader
is about 30-100 yards above ground level, the induced positive charge becomes
so concentrated that a new spark forms at the ground, as shown in Figure
2.
This positively
charged spark is the crucial process as far as the attachment to a boat
is concerned. If it starts at the tip of a boat mast, then lightning strikes
the mast. Unfortunately, there is no scientifically accepted technique
to prevent this spark from forming. Even if a device were effective in
diverting the attachment spark, it would not be a good idea to mount it
on the masthead as the attachment spark may start elsewhere on the boat
or crew. The likelihood of lightning attaching to the masthead is a safety
feature as far as the crew is concerned.
Consequently, lightning protection means minimizing
the damage caused by lightning in the event of a strike, rather than preventing
a lightning strike. In general terms, a protected boat is one in which
there is a continuous conducting path from the water to the mast tip. The
current needed to feed the attachment spark is conducted through the protection system
from the water. That is, the path that the lightning takes in the boat
is forced to be that of the conductors in the protection system. If this
conducting path is not continuous, for example, in a boat which is not
well grounded, there is little difference as far as the top of the mast
is concerned. The attachment spark still begins there as this is where
the positive charges have concentrated. The difference is what happens
where the conducting path, the mast, ends. Since current cannot flow from
the ground to feed the growing attachment spark, a negative charge accumulates
at the base of the mast and eventually arcs across in the general direction
of the water or a nearby conductor. (For this exercise, crew members are
conductors!) The result is an unharnessed electrical discharge between
the bottom of the mast and the water.
According to the above argument,
the likelihood that lightning will strike a boat does not depend on whether
the boat is well grounded or not. There is some support for this in the
experiences of marine surveyors. Nine marine surveyors in Florida, each
of whom had surveyed more than 200 sailboats in their career, reported
that between 2% and 67% (on average 34%) of the boats they surveyed for
any reason had a lightning protection system. Of the boats that they surveyed
because of a lightning strike, they reported that between 0% and 67% (on
average 29%) had a protection system. While the individual estimates varied
widely between surveyors, there is no support for the argument presented
by some sailors that they should not ground 'their sailboat since
it will increase the chances of it being struck by lightning.
__________________________________________________________
Rebuttal
Offered is a theory that an attachment spark will be produced
by either a grounded or ungrounded mast on a sailboat in about equal ratio. To support
this theory, experiences of Florida surveyors are used.
Unfortunately, I think some misinterpretation of those experiences
result which, is likely a simple oversight. The interpretation
results in a conclusion that
boats without lightning protection are being hit in a slightly higher
ratio than those with. No serious problem yet.
However, then suggested is that the data supports the theory that
both grounded and
ungrounded mast both produce an attachment spark, and therefore both
stand to take lightning strikes in a similar ratio, and if this is true
then there is no good reason not to be grounded and benefit from the
protection afforded by having a grounded mast. That necessitates
conclusions about the mast
ground condition on the boats for which the theory is supported.
It appears that it was concluded that boats with lightning protection
systems had grounded mast and those
that didn't had ungrounded mast.
The problem is that assumption doesn't account for several other reasons mast may be grounded. A
mast may be
grounded by other systems including masthead lighting, instruments,
antenna or shore power hook up, any one of which can provide incidental grounding and
a resulting attachment producing
spark. In fact, it is very likely that almost all sailboats with an
inboard
auxiliary motor will have the DC ground bonded to the engine
block with the result that any lighting, instrument or
antenna on the mast with a ground to it's mount, would then ground the
mast through the prop shaft to the water. The same is true for
an outboard equipped boat in a slip and hooked to shore power.
This means that it is theoretically possible if not likely that
most of the boats in the survey had grounded mast, therefore there is no
support afforded for Dr. Thomson's theory by these statistics.
His theory is intriguing however, and would likely find greater
acceptance among sailors if supported by valid statistical or
experiential proof. Currently in the absence of
trusted data, sailors are left divided about the issue of
non-grounded mast offering the same attraction as a grounded
mast. Protection then becomes a decision to reduce the chances of
a strike or find ways to contain the forces during a strike.
Examining the Theory
An ungrounded mast will have a finite number of free electrons compared
to a grounded mast which is being fed an unlimited supply from the
water surface. And while those electrons will be attracted to the
upper extremities of the mast by the opposing cloud potential, its
not been proven that they could sustain a spark capable of jumping to
cloud leaders especially if a single diversion point (air terminal) is not provided as
a congregating and launching point. It should be remembered, that
air while it is a good dielectric, is not a great one and will allow
free electrons to bleed off harmlessly from the mast head unless an air terminal is provided and because
of the finite number the ungrounded mast will doubtfully produce an
attachment spark. This possibility could be further
reduced by avoiding a vhf antenna (good air terminal) at the top of an ungrounded mast and
installing an ion diffuser as the upper structure.
When comparing the Florida survey statistics to those provided by Boat US for
insurance claims for example, six sailboats with auxiliary power per
thousand suffer lightning damage but only two per thousand that are
sail only. Unfortunately we still can't gleen from these
statistics an accurate account for whether a mast is grounded or
not. Other variables and explanations could also come into play.
Everything points to a need for a better survey if conclusions about
grounded or ungrounded strike ratios can be drawn to support the theory that ungrounded mast produce attachment sparks.
Statistics tell stories
Though there are no guarantees, statistics do tell a
story. Here are a few observations from some that have been kept for many years.
We know that the single greatest designated area for someone to be struck by lightning
is an open flat area. In those locations, a
person may serve as the point of discharge. Humans have good
conductivity and provide with hair sticking on end a convenient spark
attachment point. Very often accounts are narrated of the moments
prior to a strike where hair stands on end. We know also from
statistics
that farm tractors and equipment operators
are very often the victims of strikes which begs the question of why
tractors compared to cars which are seldom struck. In my opinion the answer is conductivity. Tractors are
very often working the ground with an implement and have no dielectric
resistance while cars have a high dielectric property with their
tires isolating the vehicle. The same is true for equipment
operators very often on metal tracked equipment. While very often
cars are attributed
to being safe because of their metal cage, cars are rarely reported hit even though there are so many of them. Cars have radio
antennas and many are equipped with 2-way radio or cell phone antenna and
thus have single diversion points and they have more surface than a
sailboat mast to provide free electrons and car chassis are very often
closer to
the ground than a sailboat mast. Why don't they suffer the same theory
that Dr. Thomson suggest happens on sailboats? I think the simple
answer is because they are isolated, they don't provide attachment
sparks. I think the same would be true for an ungrounded mast.
When examining the
list of the five most common places to be struck by lightning, one
factor is common... continuity to ground. Dr.
Thomson offers the awareness that most boat
lightning fatalities occur in small open boats. Why? Are
most of these aluminum and therefore no dielectric isolation
exist compared to sailboats or power cruisers which are almost all made
from fiberglass? Boat US claims indicate that runabouts which are
likely all fiberglass have only a strike rate of 2 per 10,000. How do
we reconcile that to the above statistic that most lightning fatalities
are in small open boats. One answer could be that the fatal
strikes are occurring on small aluminum boats which, may seldom be
insured by Boat US.
If my suspicion about aluminum boats is correct, then perhaps we put
too much value on height rather than conductivity. It would be
very valuable for a survey to register the kind
of craft in
use by victims of lightning strikes on the water. Those
statistics might give some perspective about conductivity and lightning.
Another significant statistic is that during 2000, there were only
three boat lightning fatalities nationally, all of which were in
Florida. These numbers are grossly less than many other areas of
boating safety, yet lightning protection is often discussed with
resulting expressions of great concern and fear. Dr. Thomson even
suggest that not to ground is perhaps subjecting oneself to litigation.
This based on his perspective that its the prudent thing to do based on
his theories. This is an easy argument with a prevailing concept
that to do nothing is an irresponsible action. Such an attitude
however totally disregards the principle that man can sometimes be his
worst enemy, doing things that bring catastrophic results. Sometimes, doing nothing, is doing the right thing.
Needed are more statistics, those which would give perspectives about
aluminum vs fiberglass. About grounded mast vs ungrounded.
Those which provide fair objectivity
to determine the validity of conclusions about sailboat and
lightning theory. Dr. Thomson's current
survey is restricted to only blue water passage makers which, likely are
all grounded. Such a survey will demonstrate only that a boat
with a heavier conductive ground system will incur less damage than one
with a poor grounding system, a foregone conclusion any one would agree with. Such a survey won't do anything to prove or
disprove his above theory.
I think a different sort of survey is
needed. One which includes
data about both hits and near misses and other pertinent data about the
boat experiencing the lightning encounter. Why near misses? If
boats with grounded mast have a lower ratio of near misses and boats with
ungrounded mast have a higher ratio of near misses, then I think that
would be significant. Such a survey would go
a long
way to giving greater perspective about the safety afforded by grounding or
ungrounding the mast on a small boat. A survey which would
include both
strikes and near misses (those defined as
having a simultaneous flash and clap) might offer some perspective to
break the deadlock of opinion between the concern that grounding
attracts and the theory that it makes no difference.
Blue Water vs Trailer Sailors
At the core of my concern are the differences between blue water and
trailer sailors. On a blue water boat, it would be difficult to
prevent either the mast or its wiring aloft from being grounded because
these boats almost always use an inboard auxiliary with the DC circuit
grounded to the engine block and with the prop immersed, the DC ground
is grounded to the water. Many blue water boats also have keel stepped
mast so the mast itself is very close and often grounded to the keel. I agree
fully that a boat with a grounded mast, should consider a lightning
protection system that provides an adequate conductive
ground. Small boats or trailer sailors usually
have decked
stepped mast that offer easy isolation and considering other factors,
it may be wise to take advantage of the option to remain ungrounded. Factors are,
- Providing a ground system with an adequate
conductive ground to provide any reasonable measure of assurance is problematic... maybe even unrealistic.
- A trailer sailor or small sailboat has little
difficulty in isolating the mast.
Small sailboats have the ease of providing an ungrounded mast because
most of them do not have an inboard motor. Outboards may or may
not provide a ground to the water. If they do, then mast
grounding may occur but trailer sailors usually have easy disconnection
points for wires routed to the mast. Ensuring an ungrounded mast
condition may involve a few procedures.
- Disconnect the mast lighting connector
- Disconnect any mast instruments
- Disconnect mast mounted antenna
- Raising the outboard from the water
A test for conductivity between the
outboard motor frame and DC ground will verify the need for any mast
disconnections. If the DC ground is isolated from the motor frame, then
unhooking the mast connection or raising the outboard would be
unnecessary. I've tested my Honda 8, 2001 model and the motor
frame is isolated and does not provide grounding to the boats
electrical system. Thus, there is no need to do any
disconnections. The mast is isolated from the water and shouldn't
produce an attachment spark with an increased risk of the mast being
struck.
There are other systems that may provide and electrical grounding and these should be checked.
- The depth sounder's transducer
- A blaster pump which draws intake from a through hull
- Speed sensor
- Water temperature sensor
- Mast compression post .... if it bonded to a
center board pivot pin. A Macgregor 26 was hit that had the
compression post grounded to the pivot pin.
Viewing the cloud and ground potentials as a capacitor
The charge potentials that cause lightning in very many ways resemble an electrical capacitor.
Capacitors are governed by
common electrical disciplines of thought. Two opposing charges
are
held at bay by an insulator having an adequate dielectric value. The
amount of capacitance (charge differences) is dictated by the size of the plates and the
kind and spacing of dielectric insulation between the plates.
If
the
insulator (dielectric) breaks down or its dielectric value becomes less than the
laws of physics allow to keep the two potentials at bay, the potential
will discharge to the opposite polarity to obtain neutral electrical
potential. Two scenarios can happen. The charge
may
increase beyond a
given dielectric resistance ability or the dielectric's value lessons
for some reason.
What
happens if a cloud rolls across the surface of the water with
almost enough potential to break down the air insulator and comes upon
a sailboat with a 30 foot mast which is not
grounded... does the air dielectric between cloud and
ground change?
Answer, Yes... slightly. Its reduced by a value of 30 feet worth
of air. Air has a dielectric value of 1.0 but is likely much less
than that when saturated with moisture. The difference between the 30
feet of aluminum mast and 30 feet worth of moisture saturated air while
perhaps significant, is not so much as other dynamics that come into
play. However, it can be noted that the sailboat with the mast is
at greater risk than a similar hull without a mast because the
dielectric difference between the cloud and ground has lessened.
As the cloud passes that boat to another with a 30 foot mast which
is
grounded, does the air dielectric change? Answer is again yes,
with a minor difference. The distance from the mast base to the
water surface would be added to the length of the mast so the
dielectric reduction is slightly more than for an ungrounded mast.
Perhaps not a big deal, unless the two boats were sailing side by
side.
The significant difference is that on a boat with the grounded mast,
free electrons from the water migrate to the masthead through the
conduction path and concentrate with the effect of greatly increasing
the voltage potential at the mast head and its upper most extremities.
In other words, the charge of the water surface has been raised
to the mast head. If an air
terminal exist at the mast head, the charge builds within it as there
is no horizontal surface to bleed the charge into the air and the
charge will become greater than that of the water surface because the
masthead is closer to the cloud and experiencing a greater attraction factor compared to the water surface.
Finally, if the charge reaches enough voltage potential to bridge
the
air dielectric gab between air terminal and a stepped leader descending
from the cloud, a connecting spark will stream upward and bridge
to the
leader providing a low resistance ion trail for the cloud discharge to
the point of the initiating streamer. It should be seen now
that the air terminal's potential becomes greater than the water
surface so it is the preferred point of providing a streamer.
With the higher voltage potential combined with a reduced
dielectric both of the listed scenarios above are fulfilled rather
than just one as on the ungrounded mast. The grounded mast then
has the potential to provide and sustain an upward streamer.
There is possibly one other area of the capacitor
illustration that may have a bearing. The dielectric resistance of the
path between leader and water surface may be less than that of the path
through the mast and boat. This may not seem right at first and contrary to what was said above but upon
examining the numbers it can be understood. Viewing a boat with a 30
foot mast and six foot of hull height the following numbers apply. The
dielectric value of air is 1.0 and that of polystyrene is 2.6. If
however, the value for air is adjusted for the greatly saturated condition
during a rain squall, to some arbitrary value lets say 1/3 its normal
value... then the dielectric ratio between the hull and six feet of
air would be (2.6 x 3) x 6 or 46.8 feet. This number would then need
to be reduced by the ratio of the length of the mast and the most air
- 30 x 0.3 or 9 feet. This means the path to ground through the
mast and hull is resistively 37.8 feet farther than a direct hit to the
nearby water surface. This may explain why a good many boats with
ungrounded mast experience near strikes.
Admittedly this assumes the lightning compared a path through both mast
and hull to that of air. If the chosen path was through the mast and
then through another six feet of air to the surface of the water, then
of course the path to ground through the mast would be shorter.
Remember, the numbers are arbitrary and would depend upon current rain
conditions. I took my very near strike during moderate rain with heavy
humid overcast.
The second illustration is an unproven theory, but so is that of Dr.
Thomson's that an ungrounded mast is supplied with a charge potential
that provides a higher voltage potential at the masthead compared to
the surrounding water.
Observations
It can perhaps be seen that from the examples above, that probabilities
may come into play... just as they do if we go into an open area or
play golf during a thunderstorm. A sailboat with an ungrounded mast has
some increased chances of being hit compared to a fiberglass
runabout. A youngster sitting in an aluminum boat with bare
feet and not wearing a cap to keep hair from standing on end would
likely be at greater risk than the sailor on a fiberglass sail boat
with an ungrounded mast. The large sailboat with a grounded mast is
most likely to be hit but the hit will be to the mast rather than to
the occupant of the boat as with the small aluminum boat.
If the large boat has adequate ground conductivity, there will be
reduced damage. Remember, that damage to modern electronics
doesn't need to take a hit... just the field surrounding a lightning
discharge can impact sensitive circuitry.
Perspective
It is important to place lightning protection systems in
perspective. One study from the National Lightning Study
Institute shows that
LIGHTNING PROTECTION SYSTEMS PROVIDE LIMITED PROTECTION.
"What we found out was that the lightning protection system played
a limited role in directing current from a lightning strike…current
traveled through the rebar, through concrete, through pipes, through
cables, through vent stacks, and through the electrical system…"
- Results of rocket-triggered testing.
These
conclusions are drawn for land
based systems that are easier to
design and implement than one for a small lightweight sailboat
and especially one in fresh water that is not very conductive and would
require a ground surface likely larger than the boat itself. For
a land based lightning protection system to provide assured
protection.... they are very intensive and very expensive. Most
systems therefore are less than assured. Limited protection means
reduced risk and damage, not elimination. The difficulties of
providing an adequate ground conductive system on a small boat in fresh
water are likely far greater than those on land, which itself is a
major challenge. One very difficult area of protection is
electronics. Lightning is not restricted to DC current, the rapid
discharge results in a momentum type action that causes several
reversals of current. Lightning also produces wide spectrum RF
frequencies as part of the discharge. These may be transmitted
from the discharge conductor or electrical wiring in the boat that is
connected to the mast lighting circuits to nearby electronics in
sufficient strength to overwhelm sensitive circuits. It is generally agreed that lightning protection systems can only reduce damage, not prevent it.
Nature of Lightning
Two separate experiences cause me to draw some
perspective. While each are personal, they both are the type that
have been repeated enough times to be common, therefore they offer
experiential value. The reader be the judge... draw upon
your own personal data base and compare.
The '70-'80s saw a proliferation of Ham radio operators using vertical
antenna on the highest point of their antenna stack to work FM 2-meter
repeaters. The great
advantage was this vertical antenna didn't need the rotator turned to
work various repeaters in adjoining communities which meant
that the HF beams could be rotated without missing out on some favorite
repeater activity.
It was thought to be a marriage made in
heaven. But, like the plaque once seen that said, marriage is
made in heaven, and so is thunder and lightning, so it proved was the
marriage of these vertical antennas to the stinger poles. They
were soon taken down... most of them by lightning. Hams took
lightning hits in unprecedented numbers, I included. I had a good friend who was a senior electrical engineer
for Rockwell International. We discussed my strike. My
tower is very close to a much taller water tower. I'd never had a
strike before, but took it shortly after installing the vertical
antenna. Why?
His answer, " When you installed the vertical
antenna, you raised ground above that of the water tower."
Say what? How could that be? He explained, "When you had a
horizontal beam as the top most antenna, the horizontal surface of that
beam antenna, dissipated the charge buildup on the antenna in a broad
harmless way. When you installed the vertical antenna, you loaded
the charge into a concentrated point with inadequate surface to
bleed off, it built up and when a cloud leader came close enough it
attracted the built up potential to jump skyward from the end of the
antenna with enough force to burn an ion trail which is a very low
resistance path. The effect was a connection to the cloud.
He also pointed out that it wasn't just the
fact that it was a vertical antenna, but rather because it was a base
loaded vertical. What this means and is the prime reason for
including this story is that the whip of the antenna was at ground
potential which provided conductivity between the ground and the tip of
the antenna. Had the antenna not been base loaded, the whip would
be isolated (not grounded) and the upper portion of my tower as far as
ground was concerned would have remained at the horizontal beam antenna
and no streamer would have been sent. I chose not to replace the
vertical on top and have never been hit again. This similar story
is repeated over and over again in the ham community. By the way,
the very popular Metz antenna used on a great many sailboat mast is a
loaded antenna and has a grounded stinger.
The lessons of this story are that to provide a single point at the top
of a mast, is to provide for streamers which have the effect of inviting a strike to HIT HERE. Dr
Thomson in fact suggest the use of an air terminal that
does exactly that. His reasoning is protection of the crew and
boat electronics by attracting the strike to hit the air terminal and
then be safely conducted to ground. Yet ,elsewhere he says, "grounding the mast as the codes dictate does
not
increase the probability of a strike".
The link in this sentence is his and the expected result is that it
would carry the reader to an explanation for his conclusion.
However, the link only takes the reader back to the general article.
In fact, another offering from the University of Florida written by William J. Becker says, " Lightning
protection systems do not prevent lightning strikes. They
may, in fact, increase the possibilities of the boat being
struck.".
While managing the strike becomes very important on blue water
sailboats that cannot avoid grounding the mast, it may be the
wrong approach for a trailer sailor that can easily remain ungrounded but having a hard time providing adequate ground.
The second account is that of a near
miss. I define a near miss
as one in which the flash and clap appear to be simultaneous.
Doing the math...for that to happen, the strike has to be within a few
hundred feet. My near miss happened as I and crew were crossing
from Michigan's lower to its upper peninsula, a passage of about forty
miles of open water. Thunder showers had not been predicted for
our area, but in mid morning they began to build to our west with some
rumbling heard in the very far distance, too far to see the
flashes so its hard to say how far.. I'm guessing at the limits of
thunder sound waves which are suggested to be
about ten miles. We were headed north and the rumblings were to
our west. About an hour after the last rumblings, rain
started falling from a fully overcast sky, the kind that
sustains rain for long periods (true in this case) and usually not
producing electrical activity. Sail was dropped to protect from
any possible high winds but winds actually lessened. We'd been
motor sailing because of limited wind anyway so the protection came at
no cost. The boat was put on autopilot and we went below to
hunker down for the three hours yet to landfall (note: my boat provides
very good
observation from within the cabin). We ate lunch and one of the
crew napped while the other and I talked.
Suddenly, a single bolt
of lightning flashed with a simultaneous very large boom. The
shock wave from the sound could be felt in the boat giving the impression we'd been struck. A quick
check showed all instruments working with the autopilot holding course and the bilge remained dry. My next reaction was to
jot down the gps coordinates on a scratch pad in case serious damage
was discovered and help was needed. My boat has an acrylic glass companionway
slide...looking up, I could see that the Windex and Metz antenna were
still in place. I breathed a sigh of relief feeling assured that
we had not taken the hit. I've asked myself numerous times, why
had this strike which was so close to the boat not hit the mast?
We heard no other strikes after it and the previous activity had ceased
an hour before it and we were fifteen miles from shore. Why when it was the single strike in such a
wide area had it been a near miss rather than a hit. Also perhaps
interesting is that the shock of the strike was felt in the hull.
This in light of the statement from this web site, " The disturbance
is a shock wave for the first 10 yards, after which it becomes an ordinary sound
wave." meant that the strike was likely within thirty feet of the
boat. Why didn't it hit the boat? I believe the answer is that
the mast was ungrounded and the boat presented a longer distance to
ground than the surrounding water surface. I've heard this
similar story repeated many times though usually its related that
lightning was hitting all around but didn't hit us.
Is there a story to tell in near misses? The forums that I have
followed the past many years are trailer sailing or small boat forums
where a great many near miss stories have been related. I wonder
if that same pattern applies to blue water sailing forums or do they
here stories of St. Elmo's fire dancing from the mast head and rigging? Again, needed is a survey with the
right questions to provide conclusions about near misses compared to
hits.
The cone of protection
I'd be remiss if I didn't cover this. Human emotions have
a need for a feeling of safety and are likely the cause to argue for a
cone of protection. Every skipper ought to feel responsible for
the safety of his crew and vessel. The idea of protection is always viable within the scope of its cost. I
certainly can't and wouldn't suggest that a measure of safety wouldn't
be provided by a cone of protection resulting from having a
grounded object overhead combined with an adequate conductive
ground. If ground continuity is inadequate,
the lightning once invited and in the process of striking WILL find a
ground. This often results in side flash as the discharge
searches for paths to ground. However, the risk involved with
side flashes appear to be less than those without a mast and if the
occurrence of hits to the mast are reduced by not attracting it, then
this may be the best of the choices.
What
measure of safety then could
be had by an ungrounded mast? According to the Sea Grant Study,
the vast majority of boat lightning deaths occur in small open boats,
and the reduction that might be afforded by ungrounding, risk should /
would
diminish even more... and diminishing risk seems to be the BUZZ word
for lightning. Of great concern is the occupant sitting in small
open boat who may become the air terminal
attracting the lightning to HIT HERE. If I were fishing
from one of these boats... I would sit on the thickest cushion money
could buy and wear the thickest soled boots available. I am a
little surprised that the Florida Sea Grant study focused more on the
lower risk sailboats than the higher risk small open boats.
Perhaps there are fewer options for the small open boat.
Arrestor
Is
keeping the mast ungrounded the simple answer for a
small boat in fresh water? No. A ground system would
likely reduce
damage and side flashing if the mast does take a hit. How can
there be a ground system without grounding the mast? By use of an
arrestor, a small air gap or dielectric that will provide for an
isolated mast but yet provide a bridge to a lightning protection
system.
Will the lightning still hit the mast if its not grounded? Yes,
statistics indicate that the ungrounded mast while less likely to be
hit will still take the hit. In my early survey conclusions, 100%
of sailboats that were hit either grounded or ungrounded, took the hit
to the mast. Because ground
systems in small freshwater sailboats are likely inadequate, its unwise
to attract
lightning to them, so using an arrestor makes sense. The arrestor
should be placed in the ground conducting path from the mast base to
the water. On a small boat in fresh water, it has been suggested
that the most effective ground is a long copper strip. Small
boats however need something flexible and easy to store.
One idea is to use copper welding cable. Not only would it meet
the easy to store requirement, but It would be very quick and easy to
deploy when needed. With 8-10 feet of
bare wire on each end and the insulation left on the out of water
section, the wire would be wrapped a couple of turns around the base of
the mast and then each end draped over the sides passing against the
side shrouds being sure that the stripped sections are not against the
shrouds. The ends would of necessity need to be as long as
possible, but short of the outboard prop. The insulation left on
the cable becomes the arrestor, keeping the mast ungrounded but yet
providing a short bridge to carry the hit to the grounding wire. Some
small holes in the insulation where it wraps around the mast would
provide a spark gap while holding the cable from bonding.
With two turns of cable around the mast and equal sections on each
side, the rubber covered cable shouldn't need any further effort to
remain in place. This would afford twenty feet of ground strap, a
good conductor without connections and an arrestor which should provide
a ready pickup for a lightning discharge.
Conclusion
Even with the small numbers of lightning strikes that cause an
injury or fatality, the dynamics of the power and results of lightning
cause great concern. Most comments on lightning and boating
include a suggestion to avoid going sailing when it might occur.
That works well for a day sailor but not as well for a coastal cruiser
and not at all for a blue water passage maker. Prudence comes in
different packages depending upon our needs and circumstances.
This is one of those times when day sailors and those who coastal
cruise on small boats very often in fresh water where providing an
adequate conductive ground is unrealistic, should be careful about half
hearted attempts to emulate their larger counterparts sailing in salt
water. A friend uses more graphic words and I don't want
this article to lean toward the emotional, but he suggest, "If you
invite the monster aboard, you better be prepared to deal with
it." I think those are very wise words. Many small boat
sailors use less than adequate schemes in the hopes that doing
something is better than nothing... that may not be true in the case of
lightning.
Boat lightning survey I
Several times in the course of this offering, I've raised the need for
survey information which may help gain perspective.
If you were the skipper, crew or witness to
an on the water lightning encounter involving any kind of boat, either
occupied or not, your participation in this survey would be
greatly appreciated. Ultimately, its hoped that the data
collected will allow a clearer perspective about several issues
regarding the nature of these occurrences.
An encounter is either a hit or near miss. A near miss is
described as a hit close enough that the flash and sound appeared to be
simultaneous.
To participate in this survey, CLICK HERE
Current Tabulations from the Survey
Though numbers are far too few to to be of much significance, here are the current numbers.
| 0 |
|
hit boat |
0% |
| 12 |
|
hit mast |
48% |
| 1 |
|
hit occupant |
4% |
| 8 |
|
near miss-hit water |
32% |
| 4 |
|
hit another boat or land |
16% |
|
|
|
|
| 1 |
|
personal injury -minor |
4% |
| 0 |
|
serious |
0% |
| 1 |
|
fatality |
4% |
| 23 |
|
no injuries |
92% |
|
|
|
|
| 18 |
|
no, or minor damage |
72% |
| 6 |
|
extensive damage |
24% |
|
|
|
|
| 1 |
|
open boat |
4% |
| 24 |
|
boat with cabin |
96% |
|
|
|
|
| 1 |
|
wood |
4% |
| 1 |
|
aluminum or steel |
4% |
| 23 |
|
fiberglass |
92% |
|
|
|
|
| 15 |
|
outboard motor |
60% |
| 10 |
|
inboard motor |
40% |
| 0 |
|
no motor |
|
|
|
|
|
| 4 |
|
equipped with LPS |
16% |
| 21 |
|
not equipped |
84% |
|
|
|
|
| 1 |
|
no mast |
4% |
| 24 |
|
has mast above head |
96% |
|
|
|
|
| 17 |
|
top object - antenna |
68% |
6
|
|
windex |
24% |
| 1 |
|
ion disfuser |
4% |
| 0 |
|
no objects on mast |
0% |
|
|
|
|
| 7 |
|
mast grounded |
28% |
| 17 |
|
mast ungrounded |
68% |
52% of respondents listed a hit, all were to mast except one small open boat which resulted in three fatalities.
Of the 12 mast hits, 9 were grounded or should be considered grounded
because they listed both an inboard and antenna on the mast. 3
were ungrounded. Grounded mast then were hit three times the rate
of ungrounded. This figure matches identically the Boat US
statistic.
48% were near misses, with 4 being grounded and 8 being ungrounded.
Ungrounded mast had twice as many near misses as grounded mast..
Of the 10 inboards, all had antenna on the mast. 4 of these reported to be grounded and 6 reported ungrounded
As has been illustrated, its very
likely that all of these boats were grounded by the antenna. Even
though this kind of ground would be ineffective at handling a lightning
strike, it may be the source of an attachment spark. This
illustrates that many inboard owners may not recognize there mast is
grounded, and that adequate ground conductivity should be provided.
The last category if adjusted to include inboards also having antenna on the mast.
- 13 mast grounded for 56%
- 11 mast ungrounded 44%
There are a
couple of questions that need added to the survey. 1. Salt water
or Fresh ? 2. Was boat hit while slipped, if so... was it
connected to shore power?
Acknowledgments
A special thanks to several people for the contribution they made in this offering.
Tom Spitznagel (cruiser) currently in the Bahamas, for arousing my concern and causing me to think
Steven Gardner (an electrician) who pointed me toward the need to
remember that a grounded mast is not dependent on a lightning
protection system but very often results from a boats normal electrical
system connected to the auxiliary or shore power.
Paul Frymier (an educator/researcher) for giving counsel on the nature
of theory and discourse. He unwittingly (perhaps not) gave me the
resolve to question Dr. Thomson's assertions in a more disciplined and
impressionable way.
Comments or Suggestions
Please send any comments or suggestions to aa5by@suddenlink.net
.Arlyn's Catalina 250